Category: PRODUK KAMI

Read more

Holip Inverter HLP-SP110 4KW

HLP-SP110 Series – 6 – 2.2 Particular Specifications Model Input voltage Input current /A Output current /A Rated power /KW Suitable motor /kW Net weight /KG HLP-SP1100D7543 3×380-440V50/60Hz 3.7 2.3 0.75 0.75 1.3 3×440-480V50/60Hz 3.2 2.1 HLP-SP11001D543 3×380-440V50/60Hz 6.4 4 1.5 1.5 1.3 3×440-480V50/60Hz 5.5 3.6 HLP-SP11002D243 3×380-440V50/60Hz 8.9 5.6 2.2 2.2 1.3 3×440-480V50/60Hz 7.7 5.1 HLP-SP11004D043 3×380-440V50/60Hz 15.8 9.9 4.0 4.0 2 3×440-480V50/60Hz 13.6 9 HLP-SP11005D543 3×380-440V50/60Hz 21.3 13.3 5.5 5.5 2 3×440-480V50/60Hz 18.4 12.1 HLP-SP11007D543 3×380-440V50/60Hz 28.3 17.7 7.5 7.5 2.5 3×440-480V50/60Hz 24.4 16.1 HLP-SP110001143 3×380-440V50/60Hz 35.9 25 11 11 5.8 3×440-480V50/60Hz 31.4 22.7 HLP-SP110001543 3×380-440V50/60Hz 43.4 32 15 15 5.8 3×440-480V50/60Hz 38.8 29.1 HLP-SP11018D543 3×380-440V50/60Hz 51.5 38 18.5 18.5 8 3×440-480V50/60Hz 46.1 34.5 HLP-SP110002243 3×380-440V50/60Hz 61.0 45 22 22 8 3×440-480V50/60Hz 54.5 40.9 HLP-SP110003043 3×380-440V50/60Hz 73 61 30 30 19 3×440-480V50/60Hz 64 52 HLP-SP110003743 3×380-440V50/60Hz 72 75 37 37 22 3×440-480V50/60Hz 65 68 HLP-SP110004543 3×380-440V50/60Hz 86 91 […]

Read more

Bender IR425-D4-2 Isometer Insulation Monitoring

Features Insulation monitoring for AC/DC control circuits 0…300 V Two separately adjustable response values Preset function (automatic setting of basic parameters) Connection monitoring system/earth LEDs: Power On, Alarm 1, Alarm 2 Internal/external test/reset button Two separate alarm relays (one changeover contact each) N/O or N/C operation, selectable Fault memory behaviour, selectable Self monitoring with automatic alarm Multi-functional LC display Adjustable response delay Two-module enclosure (36 mm) Push-wire terminal (two terminals per connection) Applications AC/DC control circuits in the industrial sector, mechanical engineering, power plants, elevators, automation systems etc. AC/DC control and auxiliary circuits in accordance with DIN EN 60204-1 “Electrical equipment of machines”, IEC 60204-1, EN 60204-1 AC/DC auxiliary circuits in accordance with DIN VDE 0100-725 (VDE 0100-725) Smaller AC/DC IT systems such as lighting systems ISOMETER® IR425-D4 Variant(s) Type Nominal system voltage* Un Supply voltage* US Response value Ran System leakage capacitance Ce Art. No.** IR425-D4-1 DC/AC 0…300 V, 15…460 Hz DC 9,6…94 V/ AC […]

Read more

Wenglor P1KH004 Reflex Sensor

The reflex sensor with background suppression works with red light according to the angle measurement principle and is suitable for the detection of objects against any background. The sensor always has the same switching distance, regardless of the color, shape and surface of the objects. Minimal height differences can be detected with the sensors and, for example, various parts can be reliably differentiated from each other. The IO-Link interface can be used to configure reflex sensors (PNP/NPN, NC/NO, switching distance) and to output switching statuses and distance values.

Read more

S1SD-1AI-2U Pepperl Fuchs Isolating Amplifier

Isolating Amplifier/Splitter Key Benefits at a Glance 1-channel signal conditioner 24 V DC supply Input 2-wire transmitters Input current and voltage sources Dual output 0/4 mA … 20 mA, 0/1 V … 5 V or 0/2 V … 10 V Signal splitter (1 input and 2 outputs) Accuracy 0.1 % Connection via screw terminals Untuk Product Pepperl Fuch Model lain bisa hubungi kami

Read more

AZ16-02ZVRK-M16 Schmersal Safety Door Switch

AZ 16-02ZVRK-M16 3 cable entries M 16 x 1.5 Large wiring compartment Thermoplastic enclosure Double-insulated 52 mm x 90 mm x 30 mm Universal coding Long life High level of contact reliability with low voltages and currents Insensitive to soiling Slotted holes for adjustment, circular holes for location Untuk Kebutuhan Schmersal Lainya bisa hubungi Kami

Read more

PSR-SCP-24DC/ESP4/2X1/1X2 Phoenix Contact

Safety relay for SIL 3 high-demand and low-demand applications, also approved in accordance with EN 50156, DNV, and EN ISO 13849, emergency stop and safety door monitoring, 1-channel, 2 enabling current paths, 1 signal contact, plug-in screw terminal blocks, width: 22.5 mm PSR-SCP- 24DC/ESP4/2X1/ 1X2 2981020 untuk Kebutuhan Phoenix Contact Lainya bisa hubungi kami  

Read more

RKC RD400 Temperature Controller

Digital Temperature controllers RD100 / RD400 / RD500 / RD700 / RD900 Brand : RKC Category : Temperature Controllers SKU : RD series(RD100 / RD400 / RD500 / RD700 / RD900) Number of input: 1 point Input type: ※See the Input Range Code for the input range. Group 1: Thermocouple K, J, T, S, R, E, B, N, W5Re/W26Re, U, L, PLII Group 2: RTD Pt100,JPt100 Sampling time: 0.25 sec. Measurement accuracy:±(0.2% of displayed value+1 digit) ※Depends on the input and the range. Alarm function (max.4 points): Temperature alarm, Heater break alarm, Loop break alarm, FAIL CT input for Heater Break Alarm : Max. 2 points Analog retransmission output: Output type is the same as OUT1 ※The signal is produced from OUT2 terminal. Digital input: Max.2 points Communication interface: RS-485

Read more

IFM VTV122 Vibration Transmitter

Product characteristics Measuring range of vibration [mm/s] 0…25; (RMS) Frequency range [Hz] 10…1000 Application Application vibration transmitter to ISO 10816 Electrical data Operating voltage [V] 9.6…32 DC Protection class III Sensor type microelectromechanical system (MEMS) Inputs / outputs Total number of inputs and outputs 1 Outputs Analogue current output [mA] 4…20 Max. load [Ω] < (Ub – 9,6 V) x 50; Ub = 24 V: 720 Measuring/setting range Measuring range of vibration [mm/s] 0…25; (RMS) Frequency range [Hz] 10…1000

Read more

Allen Bradley MSR127TP Cat 440R-N23132 Safety Relay

Relay, GuardMaster, MSR127TP, Single Function, Safety, 24 Volt AC/DC, 1 or 2 Normally Closed, Light Curtain, Inputs, 3 Normally Open, Safety Outputs, 1 Normally Closed, Auxiliary Outputs, Removable Screw Terminals, Automatic/Manual Reset Our Bulletin MSR300 family of expandable modular safety relays handles larger, more complicated safety systems by allowing connection of multiple input modules to a single base unit. It offers a logic configuration with multiple inputs and the control of multiple independent outputs. The system supports up to 20 diverse inputs and can control up to 3 zones, performing simple function block logic configurations through rotary switch settings as opposed to software configuration.

Account details will be confirmed via email.