Category: PRODUK KAMI

Read more

Pepperl Fuchs V3-GM-2M-PVC Female cordset single-ended M8 straight A-coded, 3-pin, PVC cable grey

General specifications Connector 1 Connection socket Construction type M8 Style straight Locking screw connection Number of pins 3 Coding A-coded Connector 2 Connection cable end Electrical specifications Operating voltage UB max. 48 V AC / 60 V DC Operating current IB max. 3 A Conformity Degree of protection EN 60529 Plug connection connector M8 x 1 : IEC 61076-2-104 Ambient conditions Ambient temperature Plug connector -40 … 90 °C (-40 … 194 °F) Cable, fixed -40 … 70 °C (-40 … 158 °F) Cable, flexing -5 … 70 °C (23 … 158 °F) Pollution degree 3 Mechanical specifications Plug connector

Read more

Rexroth R901017022 Rexroth PLUG-IN CONNECTOR 3P Z5L M 12-240V SP& (R901017022)

he Bosch Rexroth PLUG-IN CONNECTOR 3P Z5L M 12-240V SP& (R901017022) is a high-quality electrical accessory designed for industrial use, specifically tailored for valves with connector K in accordance with EN and ISO standards. This durable mating connector features a 3-pole + PE configuration according to EN, ensuring compatibility and a secure connection for valves equipped with one or two solenoids. The inclusion of an LED indicator provides immediate visual feedback on the connection status, enhancing operational safety and convenience. Crafted with precision, this plug-in connector supports a supply voltage range of up to 240V AC/DC, making it versatile for various electrical requirements within industrial environments. Its robust construction is reflected in the black coloration of the unit, which often denotes resistance to industrial conditions and potential soiling. The product’s weight has been optimized to contribute to its reliability without compromising on its sturdiness. As an OEM accessory, the Bosch […]

Read more

Wenglor P1KH002 Reflex Sensor with Background Suppression

The reflex sensor with background suppression works with red light according to the angle measurement principle and is suitable for the detection of objects against any background. The sensor always has the same switching distance, regardless of the color, shape and surface of the objects. Minimal height differences can be detected with the sensors and, for example, various parts can be reliably differentiated from each other. The IO-Link interface can be used to configure reflex sensors (PNP/NPN, NC/NO, switching distance) and to output switching statuses and distance values.

Read more

WEIDMULLER ACT20M-AI-2AO-S 11760220000

Input Input current configurable 0…20 mA 4…20mA Input resistance, current 70 Ω Input resistance, voltage 500 kΩ Input voltage configurable 0(2)…10 V 0(1)…5 V Number inputs 1 Sensor Voltage source Current source 2-wire transmitter (without own power supply) Sensor supply 17…28 V DC (@ 20 mA) Voltage drop <1,5 V Voltage drop, current input <1.5 V Output Cut-off frequency (-3 dB) 100 Hz Load impedance current <300 Ω per channel @ max 23mA load impedance voltage ≥ 10 kΩ Number of outputs 2 Output current configurable 0…20 mA 4…20 mA Output voltage, note configurable 0(2)…10 V 0(1)…5 V Type active connected control must be passive General data Accuracy <0.05 % of measuring range Configuration DIP switch Delivery state Setting parameters: Input Configuration: 0…20 mA (loop) Setting parameters: Output 1 Configuration: 0…20 mA Setting parameters: Output 2 Configuration: 0…20 mA Delivery state Input: 0…20 mA (loop) // Output 1: 0…20 mA […]

Read more

GESTRA NSR1-50 NSR 1-50 For One Electroda

The NRS 1-50 level switch is designed for different boiler water conductivities and for the connection of a single level electrode. If the water falls below the minimum level, the level electrode is exposed and an alarm is triggered in the level switch. This switchpoint is determined by the length of the electrode extension (level electrode NRG 1…-50). When the off delay has elapsed, the two output contacts of the level switch open the safety circuit for heating. The heating cut-off is interlocked in the external safety circuit and this interlock can only be deactivated again when the level electrode is immersed once more. In addition, the signal contact for external signaling devices closes without a delay. The NRS 1-50 level switch must be used in combination with an external manual reset when used as a protective device per ASME CSD-1. An alarm is also triggered if faults occur in […]

Read more

PULS CPS20 Series CPS20.241-D1 DC-DC Converter In: 110-300Vdc Out: 24Vdc 20A

Input data DC Input voltage DC 110 V – 300 V (± 20 %) Input inrush current limitation active Input inrush current 6 A / 4 A Output data Nominal voltage 24 Vdc Adjustment range 24 – 28 V Output current range 20 – 17.1 A Output current 17.1 A at 28 V 20 A at 24 V Output power 480 W Power reserves 20 % Power Boost Derating 12 W/°C for >+60 °C Ripple and noise voltage max. 50 mVpp Overview Dimensions (WxHxD) 65 mm x 124 mm x 127 mm Weight per unit (excl. packaging) 940 g Mounting method DIN rail Operating temp. range -25 °C to 70 °C Connection method Screw terminals Efficiency, typ. 94.6 % Power losses, typ. 27.4 W MTBF SN 29500 @ 40 °C (h) 537000 h DC-OK signal yes  

Read more

BECKHOFF EK1100 EtherCAT Coupler Beckhoff

The EK1100 EtherCAT Coupler is the link between the EtherCAT protocol at fieldbus level and the EtherCAT Terminals. The coupler converts the passing telegrams from Ethernet 100BASE-TX to E-bus signal representation. A station consists of a coupler and any number of EtherCAT Terminals that are automatically detected and individually displayed in the process image. Special features: Connection technology: 2 x RJ45 socket Connection lengths: up to 100 m Number of EtherCAT Terminals in the overall system: up to 65,535 The EK1100 has two RJ45 sockets. The upper Ethernet interface is used to connect the coupler to the network; the lower socket serves for the optional connection of further EtherCAT devices in the same segment. In addition, an EtherCAT junction or an EtherCAT extension can be used for the extension or for setting up a line or star topology. The system and field supply, each 24 V DC, is provided directly at the coupler. The attached EtherCAT Terminals are supplied with […]

Account details will be confirmed via email.